ICA Heating supplies and services the full Siemens combustion controls line across New Jersey and New York. From LMV5 linkageless burner management and LFL flame safeguards to QRI/QRA flame detectors, SKP gas valve actuators, and SQM combustion motors — backed by 50 years of hands-on combustion expertise.

900Actuator Positions
15 PTFuel-Air Ratio Curve
O2Integrated Trim
24/7ICA Service & Support
About Siemens Combustion Controls

Precision Combustion Control
for Every Burner

Siemens Combustion Controls is the global standard in burner management technology — from the LFL flame safeguard found on boilers worldwide to the LMV5 linkageless burner management system that represents the state of the art in combustion control. Their products protect people, optimize fuel efficiency, and reduce emissions on every type of commercial and industrial burner.

The Siemens combustion platform covers the complete control chain — flame safeguards, burner controllers, flame detectors, gas valve actuators, combustion air actuators, pressure switches, and sensors. Every component is engineered to work together as an integrated system, not a collection of individual parts.

ICA Heating carries the full Siemens combustion controls line and has been commissioning, tuning, and servicing Siemens-equipped boilers across NJ and NY since 1974. When your combustion system needs attention — from a routine safeguard replacement to a complete linkageless retrofit — ICA is the call to make.

Linkageless Precision
LMV5 replaces mechanical linkages with electronic actuators — 900 positions, 15-point fuel-air curves, zero drift.
Independent Safety
Flame safeguard runs on a dedicated processor — physically separated from combustion control logic. Safety cannot be compromised.
IR & UV Flame Detection
QRI infrared and QRA ultraviolet detectors for every fuel type and firing condition — from natural gas to heavy oil.
ICA Combustion Experts
50 years of commissioning, tuning, and servicing Siemens combustion systems on boilers across NJ and NY.
The Siemens Combustion Controls Line

Burner Management. Flame Safety.
Valves. Actuators. Detection.

The complete Siemens combustion control ecosystem — from flagship burner management systems to flame safeguards, detectors, gas valve actuators, and combustion motors.

Burner Management Systems
LMV5 LINKAGELESS BMS

The flagship Siemens burner management system — integrating flame safeguard, fuel-air ratio control, PID load control, O2 trim, and VFD blower control in a single platform. Controls up to 5 rotary actuators simultaneously with 900 highly repeatable positions per actuator for precision combustion.

  • ActuatorsUp to 5 simultaneous
  • Positions900 per actuator
  • Fuel-Air Points15 programmable ratio points
  • O2 TrimIntegrated
  • VFD ControlIntegrated blower VFD
  • ApplicationsSteam, hot water, thermal fluid boilers
Burner Management Systems
LMV3 BURNER CONTROL

Compact single or dual-fuel burner control with simplified commissioning and programmable purge timing up to 60 minutes. Provides parallel positioning control for up to 2 actuators with VFD blower control — ideal for mid-range commercial boilers.

  • ActuatorsUp to 2 simultaneous
  • FuelSingle or dual-fuel
  • PurgeProgrammable up to 60 min
  • VFD ControlIntegrated blower VFD
  • CommissioningSimplified setup
Flame Safeguards
LFL FLAME SAFEGUARD

One of the most widely installed flame safeguard controls in the world. Provides burner sequencing and flame monitoring for gas, oil, or dual-fuel burners with an unmatched record for safety and reliability. UL/FM/CSA approved with multiple purge timing options.

  • FuelGas, oil, or dual-fuel
  • Purge Options8s, 25–30s, or 60s
  • Voltage110V (UL/FM/CSA) or 220V (CE)
  • ApprovalsUL, FM, CSA globally
  • StatusIndustry standard worldwide
Flame Safeguards
LME7 PROGRAMMABLE SAFEGUARD

Programmable flame safeguard with UV and flame rod inputs for flexible detection. Available with optional self-check UV scanner for continuous safety verification — combining programmability with the proven Siemens safety architecture.

  • DetectionUV and flame rod inputs
  • Self-CheckOptional self-check UV scanner
  • TypeProgrammable safeguard
  • ApplicationsCommercial & industrial burners
Flame Detection
QRI INFRARED DETECTORS

Infrared flame detectors sensitive to the IR radiation emitted by natural gas and light oil combustion. The reliable standard choice for commercial and industrial burners burning conventional fuels.

  • TechnologyInfrared (IR) detection
  • Fuel TypesNatural gas, light oil
  • ApplicationsStandard commercial/industrial
Flame Detection
QRA ULTRAVIOLET DETECTORS

Ultraviolet flame detectors for applications where IR detection may be unreliable — heavy oil, low-NOx burners, or complex firing conditions with background IR radiation. The QRA75 provides definitive flame sensing in the most demanding combustion environments.

  • TechnologyUltraviolet (UV) detection
  • Fuel TypesHeavy oil, low-NOx, multi-fuel
  • ApplicationsComplex combustion environments
Gas Valve Actuators
SKP SERIES ACTUATORS

Gas safety shutoff and pressure regulation actuators mounted on VG valve bodies. The SKP15 provides safety shutoff with proof-of-closure switch. The SKP25 adds pressure regulation to 20 PSI with zero droop — functioning as a ratio regulator or governor.

  • SKP15Safety shutoff with POC switch
  • SKP25Shutoff + pressure regulation to 20 PSI
  • Valve BodiesVG series 1/2" to 6"
  • Power13.5 VA
  • FeaturesVisual position indication
Combustion Actuators
SQM SERIES MOTORS

Factory-assembled rotary actuators with zero hysteresis and positive shaft connections for precise combustion control. Paired with LMV5 and LMV3 systems for linkageless fuel-air ratio positioning — replacing mechanical linkage with electronic precision.

  • SQM390–400 in-lbs, 6 position switches
  • SQM745–160 in-lbs, NEMA 4, 3 switches
  • Input4–20mA, 24/110/220 Vac
  • FeaturesZero hysteresis, positive shaft
Technology & Advantages

Why Linkageless. Why Siemens.
Why It Matters.

The engineering advantages that make Siemens the preferred combustion control platform for mechanical engineers, contractors, and facility managers running commercial and industrial boilers.

Linkageless Control
The LMV5 eliminates mechanical linkages between fuel valves, air dampers, and flue gas dampers. Electronic actuators with 900 repeatable positions replace cams, levers, and jackshafts — delivering precise fuel-air ratio control that doesn't drift over time.
Integrated O2 Trim
Built-in oxygen trim continuously adjusts the air-fuel ratio based on real-time flue gas analysis. The result: optimized combustion efficiency across the entire firing range — not just at the commissioning setpoint.
Independent Safety Processor
The LMV5 flame safeguard runs on an independent processor — physically separated from the combustion control logic. Safety functions cannot be overridden or compromised by control system faults.
VFD Blower Integration
Integrated variable frequency drive control modulates combustion air blower speed to match firing rate. This reduces electrical consumption at low fire, lowers noise, and extends blower motor life.
Multi-Spectrum Flame Detection
QRI infrared and QRA ultraviolet detectors cover every fuel and firing condition. From standard natural gas to heavy oil, low-NOx, and multi-fuel applications — Siemens has the right flame sensing technology.
15-Point Fuel-Air Curve
The LMV5 allows 15 programmable fuel-air ratio points across the firing range — compared to the 3-5 points typical of mechanical linkage systems. More points mean tighter combustion control and lower emissions.
Need combustion controls serviced or upgraded?ICA — 50 years of burner expertise in NJ & NY.
Applications

Where ICA Installs & Services
Siemens Combustion Controls

ICA has commissioned and services Siemens combustion controls on boilers and burners in every type of facility across New Jersey and New York.

Commercial Boiler Plants
LMV5 and LMV3 systems on hot water and steam boilers in hospitals, universities, and commercial buildings across NJ and NY.
Industrial Process Heating
Thermal fluid heaters, process burners, and industrial boilers requiring precise combustion control with O2 trim and VFD integration.
Dual-Fuel Systems
Gas/oil dual-fuel boilers requiring seamless fuel changeover with automatic fuel-air ratio adjustment and interlock management.
Critical Facilities
Hospitals, data centers, and facilities requiring the highest levels of combustion safety and system redundancy.
Why Choose ICA Heating

Your Combustion Controls
Partner Since 1974

Combustion controls aren't commodity parts — they're safety-critical systems that require expertise to select, install, commission, and maintain. ICA Heating has been in boiler rooms across NJ and NY for 50 years. We know Siemens combustion systems because we work on them every day.

Whether you need a flame safeguard replaced on an existing boiler, a complete LMV5 linkageless retrofit, or a new combustion system specified and commissioned from scratch — ICA provides the engineering, the parts, and the technicians to get it done right.

Combustion Expertise Since 1974
ICA has been commissioning, tuning, and servicing burner controls on commercial and industrial boilers across NJ and NY for 50 years. We know Siemens combustion systems inside and out.
System Design & Specification
Our engineers select the right Siemens control platform for each application — matching flame safeguard, actuator, valve, and detection components to your burner, fuel type, and facility requirements.
Startup & Combustion Tuning
ICA technicians perform complete combustion commissioning — including fuel-air ratio programming, O2 trim calibration, safety interlock verification, and emissions testing to ensure code compliance.
24/7 Emergency Service
When a flame safeguard lockout shuts down your boiler at 3 AM in January, ICA answers the phone. Our technicians carry Siemens replacement parts and know how to get your system back online fast.
Frequently Asked Questions

Common Questions About
Siemens Combustion Controls

What is the Siemens LMV5 burner management system?
The LMV5 is Siemens' flagship linkageless burner management system. It integrates flame safeguard (on an independent processor), fuel-air ratio control with 15 programmable points, PID load control for temperature or pressure, integrated O2 trim, and VFD blower control — all in a single platform. It controls up to 5 rotary actuators simultaneously with 900 repeatable positions each, replacing mechanical linkages with electronic precision.
What is the difference between the LMV5 and LMV3?
The LMV5 is the full-featured platform supporting up to 5 actuators, 15 fuel-air ratio points, integrated O2 trim, and comprehensive monitoring. The LMV3 is a compact alternative for simpler applications — supporting up to 2 actuators with single or dual-fuel capability and programmable purge timing. Both provide parallel positioning control and VFD integration.
What is a flame safeguard control?
A flame safeguard is a safety device that monitors the burner startup sequence and continuously verifies flame presence during operation. If the flame is lost or fails to establish during startup, the safeguard immediately shuts off fuel flow to prevent dangerous gas accumulation. The Siemens LFL is one of the most widely installed flame safeguards in the world, with UL, FM, and CSA approvals.
When should I use QRI vs QRA flame detectors?
QRI infrared detectors are the standard choice for burners firing natural gas and light oil — they are reliable, cost-effective, and widely used. QRA ultraviolet detectors are needed for heavy oil, low-NOx burners, and complex firing conditions where background infrared radiation could cause false flame signals. Your burner type and fuel determine which detector is appropriate.
Does ICA service and repair Siemens combustion controls?
Yes. ICA Heating provides complete Siemens combustion control services across New Jersey and New York — including system design, installation, commissioning, combustion tuning, O2 trim calibration, annual inspections, and 24/7 emergency troubleshooting. Our technicians carry replacement LFL safeguards, QRI/QRA detectors, and other critical components for fast on-site repairs.
Can ICA upgrade my boiler from mechanical linkage to linkageless controls?
Yes. Retrofitting from mechanical linkage to Siemens LMV5 linkageless control is one of the most impactful upgrades you can make to an existing boiler. Linkageless control eliminates cam and linkage drift, provides tighter fuel-air ratio control across the firing range, integrates O2 trim, and typically improves combustion efficiency by 2-5% — paying for itself in fuel savings within 1-3 years.
ICA Heating — Combustion Experts Since 1974
Need Combustion Controls
Specified or Serviced?